Sage Thermal Mass Gas Flow Meters
Industrial
Heavy Industrial
General Purpose
General Purpose Blind
SIP
SRP
SIE
SRE
SIG
SRG
SIL
SRL
All products have rangeability as high as 1000 to 1, have extreme sensitivity (can measure as low as 10 SFPM or less), and are virtually unaffected by process temperature or pressure variations. The flow meters are dirt insensitive, have negligible pressure drop, and have no moving parts, assuring long term stability and sustained performance
Integral Windowed Explosion Proof Enclosure - Dual Compartment with separate terminal access
Remote Windowed Explosion Proof Enclosure - Dual Compartment with separate terminal access, and Explosion Proof Junction Box
Heavy Industrial Windowed Explosion Proof Dual Compartment
Remote Heavy Industrial Windowed Explosion Proof -Dual Compartment, and Explosion Proof Junction Box
Windowed Nema 4X Enclosure
Remote Windowed Nema 4X Enclosure with Explosion Proof Junction Box
Blind Nema 4X Enclosure
Blind Remote Nema 4X Enclosure with Explosion Proof Junction Box
Integral
Remote enclosure is Lead-Length compensated up to 1000 feet (25 feet supplied)
Integral
Remote enclosure is Lead-Length compensated up to 1000 feet (25 feet supplied)
Integral
Remote enclosure is Lead-Length compensated up to 1000 feet (25 feet supplied)
Integral
Remote enclosure is Lead-Length compensated up to 1000 feet (25 feet supplied)
24 VDC (15 VDC optional) with current dissipation of less than 100 ma, or 115VAC/230 VAC
24 VDC (15 VDC optional) with current dissipation of less than 100 ma, or 115VAC/230 VAC
24 VDC with current dissipation of less than 250 ma, or 115VAC/230 VAC
24 VDC with current dissipation of less than 250 ma, or 115VAC/230 VAC
24 VDC with current dissipation of less than 350 ma with backight on (less than 250 ma with backlight off), or 115VAC/230 VAC
24 VDC with current dissipation of less than 350 ma with backight on (less than 250 ma with backlight off), or 115VAC/230 VAC
24 VDC with current dissipation of less than 250 ma, or 115VAC/230 VAC
24 VDC with current dissipation of less than 250 ma, or 115VAC/230 VAC
Very High Contrast Photo-emissive OLED Display
Very High Contrast Photo-emissive OLED Display
2-Line Backlit LCD Display and 4 Button Menuing Keypad
2-Line Backlit LCD Display and 4 Button Menuing Keypad
2-Line Backlit Touch Screen Display and 4 Button Menuing Keypad
2-Line Backlit Touch Screen Display and 4 Button Menuing Keypad
No Display
No Display
Displays numerical and graphical Flowrate, Totalized Flow and Temperature as well as Calibration milliwatts (mw) for ongoing diagnostics
Displays numerical and graphical Flowrate, Totalized Flow and Temperature as well as Calibration milliwatts (mw) for ongoing diagnostics
Displays Flowrate, Totalized Flow and Temperature
Displays Flowrate, Totalized Flow and Temperature
Displays Flowrate, Totalized Flow and Temperature
Displays Flowrate, Totalized Flow and Temperature
No Display
No Display
SIP
SRP
SIE
SRE
SIG
SRG
SIL
SRL
4-20 ma (ground based) output of Flow Rate and Pulsed Outputs of Totalized Flow (24 VDC Solid State Transistor Drive)
4-20 ma (ground based) output of Flow Rate and Pulsed Outputs of Totalized Flow (24 VDC Solid State Transistor Drive)
4-20 ma isolated output of Flow Rate. (optionally configuable for Temperature)
4-20 ma isolated output of Flow Rate. (optionally configuable for Temperature)
4-20 ma isolated output of Flow Rate, and 4-20 ma Flow Rate of Temperature
4-20 ma isolated output of Flow Rate, and 4-20 ma Flow Rate of Temperature
4-20 ma isolated output of Flow Rate, and 0 - 5 VDC output of Temperature
4-20 ma isolated output of Flow Rate, and 0 - 5 VDC output of Temperature
Pulsed Outputs of Totalized Flow (24 VDC Solid State Transistor Drive)
Pulsed Outputs of Totalized Flow (24 VDC Solid State Transistor Drive)
One dry contact Relay suitable for Pulsed Outputs of Totalized Flow or configurable to Trip High or Trip Low
One dry contact Relay suitable for Pulsed Outputs of Totalized Flow or configurable to Trip High or Trip Low
Two dry contact Relays suitable for Pulsed Outputs of Totalized Flow or configurable to Trip High or Trip Low
Two dry contact Relays suitable for Pulsed Outputs of Totalized Flow or configurable to Trip High or Trip Low
Configurable for Pulsed Outputs of Totalized Flow (in lieu of Flow Rate and Temperature)
Configurable for Pulsed Outputs of Totalized Flow (in lieu of Flow Rate and Temperature)
Modbus Compliant RS485 RTU communications
Modbus Compliant RS485 RTU communications
RS232 Communication and Menuing Software (Sage VIP)
RS232 Communication and Menuing Software (Sage VIP)
RS232 Communication and Menuing Software (Sage VIP)
RS232 Communication and Menuing Software (Sage VIP)
RS232 Communication and Software (upon request)
RS232 Communication and Software (upon request)
Single Channel Operation
Single Channel Operation
Optionally available with up to four totally independent calibrations (Channels A through D). Meter can be calibrated with four different gases, four different configurations, or even four different sensitivities, or any combination of the above.
Optionally available with up to four totally independent calibrations (Channels A through D). Meter can be calibrated with four different gases, four different configurations, or even four different sensitivities, or any combination of the above.
Optionally available with up to four totally independent calibrations (Channels A through D). Meter can be calibrated with four different gases, four different configurations, or even four different sensitivities, or any combination of the above.
Optionally available with up to four totally independent calibrations (Channels A through D). Meter can be calibrated with four different gases, four different configurations, or even four different sensitivities, or any combination of the above.
Single Channel Operation
Single Channel Operation
SIP
SRP
SIE
SRE
SIG
SRG
SIL
SRL
Accuracy of +/- 1% of Reading +/- 0.5% of Full Scale
Accuracy of +/- 1% of Reading +/- 0.5% of Full Scale
Accuracy of +/- 1% of Reading +/- 0.5% of Full Scale per Channel
Accuracy of +/- 1% of Reading +/- 0.5% of Full Scale per Channel
Accuracy of +/- 1% of Reading +/- 0.5% of Full Scale per Channel
Accuracy of +/- 1% of Reading +/- 0.5% of Full Scale per Channel
Accuracy of +/- 1% of Reading +/- 0.5% of Full Scale
Accuracy of +/- 1% of Reading +/- 0.5% of Full Scale
Zero Calibration Self Check Diagnostics
Zero Calibration Self Check Diagnostics
Zero Calibration Self Check Diagnostics
Zero Calibration Self Check Diagnostics
Zero Calibration Self Check Diagnostics
Zero Calibration Self Check Diagnostics
Optional Diagnostics
Optional Diagnostics
Common Units of Flow Measurement: SCFM, SCFH, SCCM, NCMM, NCMH, KG/S, KG/M, KG/H, LBS/S, LBS/M, LBS/H, SLPM, SLPH
Common Units of Flow Measurement: SCFM, SCFH, SCCM, NCMM, NCMH, KG/S, KG/M, KG/H, LBS/S, LBS/M, LBS/H, SLPM, SLPH
Common Units of Flow Measurement: SCFM, SCFH, SCFD, SCCM, NCMM, NCMH, KG/S, KG/M, KG/H, KG/D, LBS/S, LBS/M, LBS/H, LBS/D, SLPM, SLPH
Common Units of Flow Measurement: SCFM, SCFH, SCFD, SCCM, NCMM, NCMH, KG/S, KG/M, KG/H, KG/D, LBS/S, LBS/M, LBS/H, LBS/D, SLPM, SLPH
Common Units of Flow Measurement: SCFM, SCFH, SCFD, SCCM, NCMM, NCMH, KG/S, KG/M, KG/H, KG/D, LBS/S, LBS/M, LBS/H, LBS/D, SLPM, SLPH
Common Units of Flow Measurement: SCFM, SCFH, SCFD, SCCM, NCMM, NCMH, KG/S, KG/M, KG/H, KG/D, LBS/S, LBS/M, LBS/H, LBS/D, SLPM, SLPH
Common Units of Flow Outputs (Not Displayed): SCFM, SCFH, SCFD, SCCM, NCMM, NCMH, KG/S, KG/M, KG/H, KG/D, LBS/S, LBS/M, LBS/H, LBS/D, SLPM, SLPH
Common Units of Flow Outputs (Not Displayed): SCFM, SCFH, SCFD, SCCM, NCMM, NCMH, KG/S, KG/M, KG/H, KG/D, LBS/S, LBS/M, LBS/H, LBS/D, SLPM, SLPH
Common Units of Totalized Flow: SCF, SCF, SCC, NCM, KG, LBS, SL
Common Units of Totalized Flow: SCF, SCF, SCC, NCM, KG, LBS, SL
Common Units of Totalized Flow: SCF, SCF, SCC, NCM, KG, LBS, SL
Common Units of Totalized Flow: SCF, SCF, SCC, NCM, KG, LBS, SL
Common Units of Totalized Flow: SCF, SCF, SCC, NCM, KG, LBS, SL
Common Units of Totalized Flow: SCF, SCF, SCC, NCM, KG, LBS, SL
Common Pulsed Outputs of Totalized Flow: SCF, SCF, SCC, NCM, KG, LBS, SL
Common Pulsed Outputs of Totalized Flow: SCF, SCF, SCC, NCM, KG, LBS, SL
Common Units of Velocity: SFPM, SFPS, NMPM, NMPS, NMPH
Common Units of Velocity: SFPM, SFPS, NMPM, NMPS, NMPH
Common Units of Velocity: SFPM, SFPS, NMPM, NMPS, NMPH
Common Units of Velocity: SFPM, SFPS, NMPM, NMPS, NMPH
Common Units of Velocity: SFPM, SFPS, NMPM, NMPS, NMPH
Common Units of Velocity: SFPM, SFPS, NMPM, NMPS, NMPH
Common Units of Velocity Outputs (Not Displayed): SFPM, SFPS, NMPM, NMPS, NMPH
Common Units of Velocity Outputs (Not Displayed): SFPM, SFPS, NMPM, NMPS, NMPH
Temperature Units: °C and °F
Temperature Units: °C and °F
Temperature Units: °C and °F
Temperature Units: °C and °F
Temperature Units: °C and °F
Temperature Units: °C and °F
Temperature Outputs (Not Displayed): °C and °F
Temperature Outputs (Not Displayed): °C and °F
NA
NA
Insertion: CSA approved for Class I, Div 1, Groups B, C, & D. (Tested & approved to CSA C22.2 No 30 & CSA C22.2 No. 142) Meters have a T3C Rating. AC Powered meters, have a T2 Rating
Insertion: CSA approved for Class I, Div 1, Groups B, C, & D. (Tested & approved to CSA C22.2 No 30 & CSA C22.2 No. 142) Meters have a T3C Rating. AC Powered meters, have a T2 Rating
NA
Insertion: CSA approved for Class I, Div 1, Groups B, C, & D. (Tested & approved to CSA C22.2 No 30 & CSA C22.2 No. 142) Meters have a T3C Rating. AC Powered meters, have a T2 Rating
NA
NA
 

To get started on your application, or contact us, use the button below on any page.

 

To view or print this page as a PDF formatted file use the button below.
Application Button
 
Print Page

 

 

Cover | Benefits | Principle of Operation | Specifications | Dimensional Drawings | Applications | Products/Models | Sage Facility


Home | Brochure | Contact Us | Application Form | Profiles | Instruction Manual | Links



All Rights Reserved. ©2002-2008 SAGE METERING, INC. 8 Harris Court, Building D1, Monterey, CA 93940
Toll Free (U.S. only): 1-866-677-SAGE (7243) . 1-831-242-2030 . Email:sales@sagemetering.comGeneral Terms