SIP In-Line Models / Specifications
Models
Pipe Size x
Flow Body Length1 or
Flange
(Face-to-Face)
In-Line Models
Max Full Scale (SCFM)2, 3
1/4" x 6" SIP-025 8
3/8" x 6" SIP-030 15
1/2" x 7" SIP-050 30
3/4" x 7" SIP-075 140
1" x 8" SIP-100 200
1-1/4" x 10" SIP-125 300
1-1/2" x 12" SIP-150 470
2" x 12" SIP-200 820
2-1/2" x 12" SIP-250 1000
3" x 12" SIP-300 1750
4" x 12" SIP-400 3150
1 - Flow Conditioning built in to Flow Meter pipe sizes 3/4" and up
2 - Max Full Scale available for many gases, such as pressurized Air or Nitrogen. Some gases such as Hydrogen may be limited. Contact Sage for details. Calibrations above 500 SCFM may be extrapolated
3 - SCFM = Standard Cubic Feet Per Minute. 1 SCFM = 1.7 NCMH. Sage standard conditions for calibration are 70°F and 29.92" Hg. Note, Max Full Scale is based on a maximum Velocity of 35,000 Standard Feet Per Minute (SFPM)
 
Specifications
 
General
Function Microprocessor-based In-Line Mass Flow Meters for gases
Flow Element Constant Temperature Thermal Mass Flow Element consists of two
316 SS clad platinum-wound RTDs
Flow Rate Output Signal 4-20 ma (ground based) output of Flow Rate and Pulsed Outputs of Totalized Flow (24 VDC Solid State Transistor Drive)
Pulsed Outputs Pulsed Outputs of Totalized Flow
(24 VDC Solid State Transistor Drive)
Power 24 VDC (15 VDC optional) with current dissipation of less
than 100 ma, or 115VAC/230 VAC
Temperature Optional 4-20 ma (non-isolated) and 1-5 VDC outputs proportional to
Temperature instead of FLow Rate
Communication ModbusR compliant RS485 RTU Communication
Sensor Drive Circuit Proprietary Sensor Drive Circuit provides enhanced flow signal stability and insensitivity to process temperature changes
Display Very High Contrast photo-emissive OLED display, visible even in bright sunlight
 
Flow Range / Sizes
Units of Measurement Flow–SCFM, SCFH, SCCM, NCMM, NCMH, KG/S, KG/M, KG/H, LBS/S, LBS/M, LBS/H, SLPM, SLPH, BTU/H; Temperature–°C and °F
In-Line Meters Full Scale up to 3150 SCFM (4" Flow Meter). Resolve as low as .003 SCFM (1/4" Flow Meter). Male NPT fittings standard. 150# and 300# flanged ends optional
 
Performance
Standard Flow Accuracy +/-1% of Reading +0.5% of Full Scale over 100: 1 turndown.
(Contact Sage for special accuracy)
Repeatability 0.2% of Full Scale
Turndown Up to 1000:1
Calibration Sage Metering’s National Institute of Standards Traceable (NIST) calibration facility
Gas Temperature Std.: -40°F to 200°F (-40°C to 93°C ); HT01: 200°F to 350°F (93°C to 177°C )
Integral Enclosure Temperature 0° to 150°F (-18°C to 65°C ). Contact Sage for lower temperature ranges.
Pressure Rating 500 psig (1000 psig optional)
Response Time 1 second (each time constant) for flow change
Enclosure Dual Sided Explosion Proof Enclosure with large, easy to access
terminals in rear compartment
Wetted Parts 316L Stainless Steel for Flow Bodies, Sensor Flow Elements and Flow Conditioners. Hastelloy (recommended for Chlorine Gas) and other materials optional
Limited Warranty Sage Metering's Series of Thermal Mass Flow Meters are warranted against faulty materials or workmanship for one year from the date of delivery to the buyer. After issuance of a Return Meter Authorization (RMA) by Sage, and upon receipt of the defective meter, Sage will either repair or replace the defective meter at its sole option and at no cost to the purchaser

To get started on your application, or contact us, use the button below on any page.

 

To view or print this page as a PDF formatted file use the button below.
Application Button
 
Print Page

 

Home | Brochure | Contact Us | Application Form | Profiles | Instruction Manual | Links


All Rights Reserved. ©2002-2008 SAGE METERING, INC. 8 Harris Court, Building D1, Monterey, CA 93940
Toll Free (U.S. only): 1-866-677-SAGE (7243) • 1-831-242-2030 • Email:sales@sagemetering.com General Terms